FACIAL ANTI-AGING SYSTEM

What is it?

CARELIKA Facial Anti-Aging System is an advanced skincare device equipped with several functionalities to target the signs of aging and improve skin health. It is designed for professional use, offering treatments such as skin lifting and firming, wrinkle reduction, moisture enhancement, dermabrasion, cooling and repair, peeling and cleaning, and the removal of dark circles. With a power specification of 75W and a voltage of 220V 50Hz, this system provides a powerful yet safe platform for skin rejuvenation.

Each function is carefully designed to address specific skin concerns, from aging and wrinkles to dark circles and dryness, making the CARELIKA Facial Anti-Aging System a versatile tool in the realm of professional skincare.

What does it do?

  • Diamond Microdermabrasion: Utilizes diamond peeling tips to exfoliate the skin, removing dead skin cells and promoting cell renewal for a smoother, firmer appearance.
  • Vacuum Massage: Aids in lymphatic drainage and improves circulation, resulting in reduced wrinkles and firmer skin.
  • Ultrasonic Scrubber: Offers deep cleansing and moisture infusion, utilizing ultrasonic waves to exfoliate and hydrate the skin.
  • Bipolar RF Lifting: Utilizes radiofrequency energy to heat the dermis and stimulate collagen production, tightening and firming the skin.
  • Needle-Free Mesotherapy for Face and Eyes: Employs electroporation to enhance the absorption of serums, maximizing their effects without the need for injections.
  • Cooling Treatment: Calms the skin, controls sebum, and enhances repair, providing a soothing finish to the treatments.
  • Microcurrent Therapy: Uses low-voltage currents to lift and firm the skin, reducing wrinkles and improving skin tone.
How to use it?

Prepare the Skin:

  • Cleanse the skin thoroughly to remove makeup and impurities.
  • Pat the skin dry before proceeding with the treatments.

Diamond Microdermabrasion:

  • Choose the appropriate diamond peeling tip and attach it to the handpiece.
  • Gently move the handpiece over the skin, focusing on areas with wrinkles or uneven texture.
  • Use for 15-20 minutes, depending on the skin's condition.

Vacuum Massage:

  • After microdermabrasion, attach the vacuum massage head.
  • Move the device in gentle, upward strokes to promote lymphatic drainage and firm the skin.
  • Continue for 15-20 minutes, focusing on areas needing lifting and firming.

Ultrasonic Scrubber:

  • Select the scrubber frequency suitable for your skin type.
  • Glide the scrubber gently over the skin, focusing on peeling and cleaning.
  • For phonophoresis, apply a suitable serum before using the device to enhance product absorption.

Bipolar RF Lifting:

  • Adjust the device to the RF lifting function.
  • Move the device in circular motions over areas prone to wrinkles and sagging.
  • Use for 15-20 minutes, adjusting the temperature according to skin sensitivity.

Needle-Free Mesotherapy (Face and Eyes):

  • Choose the appropriate serum for your skin concern and apply it to the treatment area.
  • Set the device to the mesotherapy mode and gently move it over the face or around the eyes.
  • Continue for 15-20 minutes to allow for maximum serum absorption.

Cooling Treatment:

  • After all treatments, switch to the cooling function to soothe and calm the skin.
  • Move the cooling head over the entire face to reduce any redness and lock in moisture.
  • Use for 10-15 minutes for a refreshing finish.

BIO Round Head Face Lift Microcurrent Therapy:

  • Select the microcurrent therapy mode suitable for your treatment area (face or eyes).
  • Glide the device over the skin, focusing on lifting and firming movements.
  • Continue for 10-15 minutes to achieve a toned and lifted appearance.

Aftercare:

  • Apply a moisturizer or a post-treatment mask to hydrate and protect the skin.
  • Use sunscreen if going outdoors to protect the skin from UV damage.

Remember, the key to achieving the best results with the CARELIKA Facial Anti-Aging System is consistency and proper technique. Always refer to the device's manual for detailed instructions and contraindications before starting any treatment.

Modes

Dermabrasion Operation

  • Purpose: Exfoliates the skin, removing the outer layer to promote new cell growth.
  • Steps: Adjust work time, select area and function, and adjust vacuum level. Move the probe as instructed for effective exfoliation.

Scrubber Operation

  • Purpose: Cleanses and exfoliates the skin using ultrasonic vibration, enhancing skin texture and appearance.
  • Steps: Choose the scrubber part, set time and intensity, and apply with medium on the skin for deep cleaning and moisturizing.

Bipolar RF Operation

  • Purpose: Uses radiofrequency to heat the skin, encouraging collagen production and skin tightening.
  • Steps: Select Bipolar RF part, adjust settings, and apply with medium on the skin for lifting and firming.

Mesotherapy Face and Eye Operation

  • Purpose: Enhances the absorption of skincare products through electroporation, improving skin hydration and nutrition.
  • Steps: Choose the appropriate mesotherapy part, adjust settings, and use with skincare products for maximum effectiveness.

Cooling Treatment Operation

  • Purpose: Soothes and calms the skin after treatments, reducing redness and locking in moisture.
  • Steps: Select the cooling treatment part, adjust settings, and gently move the probe over the skin for a cooling effect.

BIO Roller Operation

  • Purpose: Stimulates the skin through microcurrent therapy, enhancing elasticity and reducing wrinkles.
  • Steps: Select BIO Roller part, adjust settings, and follow specific movements to target wrinkles and lift the skin.

BIO Round Operation

  • Purpose: Focuses on tightening and rejuvenating the eye area, reducing puffiness and smoothing wrinkles.
  • Steps: Choose BIO Round part, adjust settings, and apply specific techniques to improve the eye area's appearance.


Each mode is designed with specific goals in mind, from exfoliation and deep cleansing to lifting, firming, and cooling the skin. For successful outcomes, it's crucial to adhere to the recommended operation steps, including adjusting the work time, intensity, and proper movement of the probes, as well as applying appropriate mediums or skincare products as needed.

Contraindication

Do not use in the following cases:

  1. The people with pacemaker or internal defibrillator;
  2. The operation body part has metal implant (such as gold wire, metal teeth);
  3. The people with skin cancer or precancerous lesions;
  4. The people with severe hypertension, diabetes, heart disease, etc;
  5. Pregnant or lactating women;
  6. The operation body part with bacteria, viruses, open wounds, etc;
  7. The operation body part with permanent fillers, or temporary fillers (consult yourdoctor first);
  8. Recently (in 3 months) treatment with hydroxy acid, laser skin resurface, chemicalexfoliation or wound healing;
  9. Do not use blood anticoagulant or isotretinic acid (retinoic acid) taken in the past 2months;
  10. It is forbidden to hold the working handle on one place on the skin for a long time.
Product Parameters
  • Power: 75W
  • Voltage: 220V 50Hz
  • Electric current: 2A
  • MEAS: 77x45x35 cm
  • Net weight: 12 kg
  • Gross weight: 15 kg